Introduction of Gas Chromatographs for Mask Ethylene Oxide Residue Detection
Introduction of Gas Chromatographs for Mask Ethylene Oxide Residue Detection

Introduction of Gas Chromatographs for Mask Ethylene Oxide Residue Detection

Brand:NANBEI

Model:NB-4000A

Application:

product details

Introduction of Gas Chromatographs for Mask Ethylene Oxide Residue Detection
       
  NB-4000A Gas Chromatographs               Head-space sampler
 
Main features
-Five detectors to choose (TCD, FID, FPD, NPD, ECD)
-Unit-type overall structure design, convenient for installation and maintenance
-Large-volume column box, three chromatographic columns can be installed at the same time.
-The design of the instrument is reasonable and flexible, and any three detectors can be installed at the same time, and there are three independent circuit systems and three signal output terminals.
-Flexible packed column and capillary column system can be connected with capillary columns of different calibers.
-Stable temperature control system, 10-stage temperature program, sampler and each detector can be independently controlled temperature, and has over-temperature protection function.
The heating zone can be controlled by seven channels
-The host automatically ignites analysis through the workstation
-Strong expansibility, the instrument can be upgraded to GC/MS
Inlet: Magnetic fixed sampling system is adopted.
4. Detector
4.1. Hydrogen flame detector
4.1.1 Detection limit: M≤1×10-11 g/s (n-hexadecane)
4.1.2 Noise: ≤5×10-14A
4.1.3 Linear range: 107
4.1.4 Drift: 1×10-13 A/30min
Column thermostat
Oven volume: 300×300×200mm
Temperature range: room temperature +5℃-400℃
Overheating protection: any temperature within 400℃ can be set
Temperature control accuracy: 0.1℃
Heating program: 10 steps
Heating rate: 0-40°C/min (incremental 0.1°C/min)
The Quotation of Epoxy Acetylene Detection NB-4000A Gas Chromatographs
 
Serial No. Product Name Specification Quantity Performance Description
1 Gas chromatographs NB-4000A 1 set Chromatograph host
Ten-stage heating
Large screen LCD display
Over temperature protection
Back door
2 Detector FID 1 set  
3 Automatic ignition button   1 set  
4 Chromatography workstation software Original factory workstation software 1 set  
5 Capillary sampling device   1 set  
6 Capillary column   1 set Ethylene oxide detection
7 Spare parts   1 piece  
8 Head-space sampler EW-2HS 1 set  
9 Bayonet pliers   1 piece  
10 Aluminum cap   1 pack  
11 Rubber stopper   1 pack  
12 Air Air + 40L cylinder + valve 1 bottle  
13 High purity hydrogen Hydrogen +40L cylinder + valve 1 bottle  
14 High purity nitrogen Nitrogen +40L  cylinder + valve 1 bottle  
15 Computer Brand 1 set  
Remarks: The installation and debugging of chemical glass reagents and standard products are all prepared by the user.
 
 
 
 
 