Introduction:
BJ series of instruments are used for detecting disintegration of solid in prescriptive conditions.
Applicable standards:
*National standard( Chinese codex ) /2010
*Corporate standard(Dissolution tester )Q/12XQ0188-2010
Model:BJ-1
Features:
There are six tubes in one basket assembly.
Auto stop at timing point.
The bath liquid can achieve an even temperature.
A MPU is used to automatically control the temperature, time and frequency of nacelle back and forth.
Timing at will. The preset and real time data can be displayed alternately in time.
Automation: auto-test, auto-diagnose, auto-alarm.
Specifications:
Basket assembly 1
Nacelle back and forth frequency (30~32) /min
Nacelle back and forth range (55±1)mm
Automatic time range (5~120)min
Accuracy of controlling temperature (37±0.5)℃
Power 220V/ 50Hz/ 600W or 110V/ 60Hz/ 600W
Dimension (260×300×420)mm3
Model:BJ-2
Features:
There are twelve tubes in two basket assembly.
Each test station is driven independently. Auto stop at timing point.
The bath liquid can achieve an even temperature.
A MPU is used to automatically control the temperature, time and frequency of nacelle back and forth.
Timing at will. The preset and real time data can be displayed alternately in time.
Automation: auto-test, auto-diagnose, auto-alarm.
Specifications:
Basket assembly 2
Nacelle back and forth frequency (30~32) /min
Nacelle back and forth range (55±1)mm
Automatic time range (5~120)min
Accuracy of controlling temperature (37±0.5)℃
Power 220V/ 50Hz/ 600W or 110V/ 60Hz/ 600W
Dimension (400×300×420)mm3
Model:BJ-3
Features:
There are eighteen tubes in three basket assembly.
Each test station is driven independently. Auto stop at timing point.
The bath liquid can achieve an even temperature.
A MPU is used to automatically control the temperature, time and frequency of nacelle back and forth.
Timing at will. The preset and real time data can be displayed alternately in time.
Automation: auto-test, auto-diagnose, auto-alarm.
Specifications:
Basket assembly 3
Nacelle back and forth frequency (30~32) /min
Nacelle back and forth range (55±1)mm
Automatic time range (5~120)min
Accuracy of controlling temperature (37±0.5)℃
Power 220V/ 50Hz/ 600W or 110V/ 60Hz/ 600W
Dimension (540×300×420)mm3
The other models we supply: